Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
S. Afr. j. child health (Online) ; 13(3): 125-129, 2019. ilus
Article in English | AIM | ID: biblio-1270368

ABSTRACT

Background. There are inconsistent published data describing the influence of maternal anaesthetic type during caesarean section (CS) on outcomes of preterm neonates. Objectives. To describe indications and type of anaesthesia in preterm neonates, and their short-term outcomes, comparing spinal anaesthesia (SA) to general anaesthesia (GA). Methods. Data were collected retrospectively on preterm babies born at 28 - 35 weeks' gestation by CS between 1 January and 30 September 2014 at Groote Schuur Hospital, Cape Town, South Africa. Babies with missing data were excluded. The largest group of babies with similar indications for delivery were identified from the theatre register. Baseline characteristics and short-term outcomes for this group were extracted from an existing prospective data base, and compared between those delivered under SA and GA. Results. Data were available for 226 deliveries, having excluded 23 with incomplete data. Most babies (75%) were delivered under SA. The most common indication for CS was 'cardiotocograph abnormalities', in 139 deliveries. Within this group, SA was the more frequent (81.7% v. 12.9%), while GA was associated with lower Apgar scores (p<0.001) and more intubation at birth (p=0.004). There was no difference in mortality when comparing SA with GA. Conclusion. Our data suggest a sedative effect of maternal GA on preterm babies delivered by CS, and the need for staff with advanced resuscitation skills. This study provides novel baseline data in our setting, but these data need to be validated in a prospective study


Subject(s)
Anesthetics , Cesarean Section , Infant , South Africa , Tertiary Care Centers
2.
S. Afr. j. sports med. (Online) ; 109(9): 652-658, 2019. ilus
Article in English | AIM | ID: biblio-1270901

ABSTRACT

Background. Despite preventive measures and effective treatment, congenital syphilis continues to impact significantly on neonatal morbidity and mortality. There has been no recent South African (SA) published literature reviewing congenital syphilis, particularly in the context of a tertiary neonatal setting. Objectives. To describe the clinical features of symptomatic neonates with congenital syphilis and to identify modifiable patient, clinical and health facility factors that contributed to syphilis infection. Methods. All positive serological tests for syphilis performed in neonates at Groote Schuur Hospital (GSH), Cape Town, SA, between 1 January 2011 and 31 December 2013 were obtained. Folders were reviewed, and neonates with clinical signs of congenital syphilis were included. Results. Of 50 symptomatic neonates, 19 (38%) died. Twenty-eight mothers (56%) were unbooked and therefore received no antenatal care. Most mothers (98%) were inadequately treated. Health worker-related failures included poor notification and partner tracing as well as failure to recheck syphilis serology after 32 weeks' gestation in mothers who initially tested negative. Thirty-four neonates required intensive care unit admission. Two significant predictors of mortality were 1-minute and 5-minute Apgar scores <5. Hydrops fetalis was an independent risk factor for mortality, as were moderate to severely abnormal cranial ultrasound scan findings. Conclusions. Congenital syphilis in neonates admitted to the GSH neonatal unit was associated with substantial morbidity and mortality. The modifiable factors identified represent inadequate antenatal healthcare and health system failures. These factors are longstanding, highlighting the need to establish governance and audit processes and address the continuing socioeconomic and sociocultural barriers that mothers face as a way forward in ultimately eliminating this entirely preventable disease


Subject(s)
Critical Care Outcomes , Morbidity , South Africa , Syphilis, Congenital
3.
S. Afr. med. j. (Online) ; 107(10): 900-903, 2017.
Article in English | AIM | ID: biblio-1271136

ABSTRACT

Background. The Groote Schuur Hospital (GSH) neonatal nursery provides level 3 care for the Metro West Health District in the Western Cape Province of South Africa. Worldwide, very-low-birth-weight (VLBW) neonates delivered in level 3 neonatal units have better outcomes than those transported from other facilities.Objectives. To identify the characteristics and outcomes of VLBW neonates at GSH, with emphasis on differences between inborns and outborns. Methods. This was a retrospective cohort study. VLBW neonates admitted to the GSH neonatal nursery between 1 January 2012 and 31 December 2013 were enrolled on the Vermont Oxford Network database and reviewed.Results. Of 1 032 VLBW neonates enrolled, 906 (87.8%) were delivered at GSH and 126 (12.2%) were outborn. Access to antenatal care, antenatal steroids and inborn status were statistically significant predictors of mortality and survival without morbidity. The mothers of inborn patients were more likely than those of outborn patients to have received antenatal care (89.1% v. 57.9%; p<0.0001) and antenatal steroids (64.2% v. 15.2%; p<0.0001). Inborns required less ventilatory support (16.2% v. 57.9%; p<0.0001) and surfactant administration than outborns (25.3% v. 65.1%; p<0.0001), and developed less late infection (8.8% v. 23.4%; p<0.0001), severe intraventricular haemorrhage (3.7% v. 13.9%; p<0.0001) and chronic lung disease (5.3% v. 13.4%; p=0.003). The incidence of necrotising enterocolitis was similar in the two groups (5.9% v. 8.7%; p=0.227). The mortality rate was 18.4% for inborns and 33.3% for outborns (p<0.0001). Mortality declined as birth weight increased. Of the survivors, 85.0% of inborns and 70.2% of outborns did not develop serious morbidity (p=0.003).Conclusions. VLBW neonates delivered at GSH had better outcomes than their outborn counterparts. Perinatal regionalisation is beneficial to our patients, with antenatal care, timeous transfer in utero and antenatal steroids contributing to excellent outcomes


Subject(s)
Infant, Very Low Birth Weight , Nurseries, Infant , Perinatal Care , Premature Birth , South Africa
SELECTION OF CITATIONS
SEARCH DETAIL